Colophony or Rosin Based Solder Flux Fume is a known cause of occupational asthma and as such exposure to it should be controlled. An effective method of engineering exposure control is to use local exhaust ventilation (LEV) to extract the fume at source. Personal exposure to solder fume was quantitatively measured in the breathing zone of a manikin, these exposures were then compared to those caused by uncontrolled soldering in order to assess five different LEV systems. The five LEV systems tested were a downdraught bench; an extracted bench top enclosure, a mobile capturing hood, an on-tip extraction system and a bench top fume absorber.
The Health and Safety Executive (HSE) are the government body responsible for the regulation and enforcement of work related risks to people in the work place. Dust & fume exposure is a key element of the COSHH 2002 (Control of Substances Hazard to Health) regulations setting out exposure limits, preventative guidelines and on going reductions of the contact between people and hazardous gas and particulates. Under COSHH, companies must take steps to prevent, control, maintain and monitor dust and fume exposure in the workplace, as laid out in regulation 9.
A comprehensive LEV report will also be produced for each piece of LEV equipment tested. All of our LEV reports include photos and/or schematic diagrams showing all test point locations, which are also clearly identified on the ducting as required by the HSE. This includes the following in line with guidance from HSG258: Following an inspection, our professional LEV consultant will mark the LEV system as a pass or fail. We will also assist you in improving all control measures where necessary.
Equipment that draws pollutants from an operation or process in the working environment. Made up of an inlet like a hood, slit, arm, cabinet or booth. This will be located near to or close to the area of the substance release. All suchlike equipment needs to be connected by ducting and a fan to enable the movement of air. The removed air passed through a filter or is extracted to atmosphere away from the workplace. How Welding Supplies Direct can help ? WE will carry out a thorough tests in line with COSHH Regulation 9 as detailed in HSE Guide HSG258 Our levels of service can be tailored to your Companies needs. However, most clients choose to take advantage of by combining servicing with the LEV testing. See more details at HSE LEV Testing.
Where employers use or intend to use LEV they must ensure that it is appropriate for the task, installed and operated correctly and subsequently maintained so it continues to operate as when originally installed. Suppliers of LEV can play an important role in helping the employer with the design, installation and maintenance of the equipment. This guidance is therefore intended to help employers and suppliers as well as managers, trade union and employee safety representatives to work together to provide effective LEV so that workers are not breathing in hazardous substances. Different chapters will be more appropriate for different audiences.